AJSM signin
HOME HELP CONTACT US SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Sign In to gain access to subscriptions and/or personal tools.
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Stadelmaier, D. M.
Right arrow Articles by Kohl, H. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Stadelmaier, D. M.
Right arrow Articles by Kohl, H. W., III
Related Collections
Right arrow Biomechanics
Right arrow Graft fixation
The American Journal of Sports Medicine 27:778-783 (1999)
© 1999 American Orthopaedic Society for Sports Medicine

Cyclic Pull-Out Strength of Hamstring Tendon Graft Fixation with Soft Tissue Interference Screws

Influence of Screw Length

Denise M. Stadelmaier, DO*, Walter R. Lowe, MD, Omer A. Ilahi, MD, Philip C. Noble, PhD and Harold W. Kohl, III, PhD

Baylor Sports Medicine Institute, Department of Orthopedic Surgery, Baylor College of Medicine, Houston, Texas

* Address correspondence and reprint requests to Denise M. Stadelmaier, DO, Atlas Orthopedics and Sports Medicine, 3660 Guion Road, Indianapolis, IN 46222

Blunt-threaded interference screws used for fixation of hamstring tendons in anterior cruciate ligament reconstructions provide aperture fixation and may provide a biomechanically more stable graft than a graft fixed further from the articular surface. It is unknown if soft tissue fixation strength using interference screws is affected by screw length. We compared the cyclic and time-zero pull-out forces of 7 x 25 mm and 7 x 40 mm blunt-threaded metal interference screws for hamstring graft tibial fixation in eight paired human cadaveric specimens. A four-stranded autologous hamstring tendon graft was secured by a blunt-threaded interference screw into a proximal tibial tunnel with a diameter corresponding to the graft width. Eight grafts were secured with a 25-mm length screw while the other eight paired grafts were secured with a 40-mm length screw. During cyclic testing, slippage of the graft occurred as the force of pull became greater with each cycle until the graft-screw complex ultimately failed. All grafts failed at the fixation site, with the tendon being pulled past the screw. There were no measurable differences in the mean cyclic failure strength, pull-out strength, or stiffness between the two sizes of screws. Although use of the longer screw would make removal technically easier should revision surgery be necessary, it did not provide stronger fixation strength than the shorter, standard screw as had been postulated.




This article has been cited by other articles:


Home page
Am J Sports MedHome page
P. Niedzwietzki, T. Zantop, A. Weimann, M. Herbort, M. J. Raschke, and W. Petersen
Femoral Fixation of Hamstring Grafts in Posterior Cruciate Ligament Reconstruction: Biomechanical Evaluation of Different Fixation Techniques: Is There an Acute Angle Effect?
Am. J. Sports Med., May 1, 2007; 35(5): 780 - 786.
[Abstract] [Full Text] [PDF]


Home page
Am J Sports MedHome page
A. K. Eggers, C. Becker, A. Weimann, M. Herbort, T. Zantop, M. J. Raschke, and W. Petersen
Biomechanical Evaluation of Different Fixation Methods for Tibial Eminence Fractures
Am. J. Sports Med., March 1, 2007; 35(3): 404 - 410.
[Abstract] [Full Text] [PDF]


Home page
Am J Sports MedHome page
H. C. Chang, J. Nyland, A. Nawab, R. Burden, and D. N. M. Caborn
Biomechanical Comparison of the Bioabsorbable RetroScrew System, BioScrew XtraLok With Stress Equalization Tensioner, and 35-mm Delta Screws for Tibialis Anterior Graft-Tibial Tunnel Fixation in Porcine Tibiae
Am. J. Sports Med., July 1, 2005; 33(7): 1057 - 1064.
[Abstract] [Full Text] [PDF]


Home page
J Bone Joint Surg BrHome page
A. Harvey, N. P. Thomas, and A. A. Amis
Fixation of the graft in reconstruction of the anterior cruciate ligament
J Bone Joint Surg Br, May 1, 2005; 87-B(5): 593 - 603.
[Full Text] [PDF]


Home page
Am J Sports MedHome page
E. S. B. Saweeres, J. H. Kuiper, R. O. Evans, J. B. Richardson, and S. H. White
Predicting In Vivo Clinical Performance of Anterior Cruciate Ligament Fixation Methods From In Vitro Analysis: Industrial Tests of Fatigue Life and Tolerance Limits Are More Useful Than Other Cyclic Loading Parameters
Am. J. Sports Med., May 1, 2005; 33(5): 666 - 673.
[Abstract] [Full Text] [PDF]


Home page
Am J Sports MedHome page
G. Camillieri, E. G. McFarland, L. E. Jasper, S. M. Belkoff, T. K. Kim, P. B. Rauh, and P. P. Mariani
A Biomechanical Evaluation of Transcondylar Femoral Fixation of Anterior Cruciate Ligament Grafts
Am. J. Sports Med., June 1, 2004; 32(4): 950 - 955.
[Abstract] [Full Text] [PDF]


Home page
Am J Sports MedHome page
T. Zantop, A. Weimann, M. Rummler, J. Hassenpflug, and W. Petersen
Initial Fixation Strength of Two Bioabsorbable Pins for the Fixation of Hamstring Grafts Compared to Interference Screw Fixation: Single Cycle and Cyclic Loading
Am. J. Sports Med., April 1, 2004; 32(3): 641 - 649.
[Abstract] [Full Text] [PDF]


Home page
Am J Sports MedHome page
J. T. Nurmi, H. Sievanen, P. Kannus, M. Jarvinen, and T. L. N. Jarvinen
Porcine Tibia Is a Poor Substitute for Human Cadaver Tibia for Evaluating Interference Screw Fixation
Am. J. Sports Med., April 1, 2004; 32(3): 765 - 771.
[Abstract] [Full Text] [PDF]


Home page
Am J Sports MedHome page
F. Adam, D. Pape, K. Schiel, O. Steimer, D. Kohn, and S. Rupp
Biomechanical Properties of Patellar and Hamstring Graft Tibial Fixation Techniques in Anterior Cruciate Ligament Reconstruction: Experimental Study With Roentgen Stereometric Analysis
Am. J. Sports Med., January 1, 2004; 32(1): 71 - 78.
[Abstract] [Full Text]


Home page
Am J Sports MedHome page
J. H. Lubowitz, D. Guttmann, T. L. N. Jarvinen, P. Kousa, P. Kannus, and M. Jarvinen
The fixation strength of six hamstring tendon graft fixation devices in anterior cruciate ligament reconstruction: parts I and II.
Am. J. Sports Med., September 1, 2003; 31(5): 811 - 811.
[Full Text] [PDF]


Home page
Am J Sports MedHome page
P. Kousa, T. L. N. Jarvinen, M. Vihavainen, P. Kannus, and M. Jarvinen
The Fixation Strength of Six Hamstring Tendon Graft Fixation Devices in Anterior Cruciate Ligament Reconstruction: Part I: Femoral Site
Am. J. Sports Med., March 1, 2003; 31(2): 174 - 181.
[Abstract] [Full Text] [PDF]


Home page
Am J Sports MedHome page
P. Kousa, T. L. N. Jarvinen, M. Vihavainen, P. Kannus, and M. Jarvinen
The Fixation Strength of Six Hamstring Tendon Graft Fixation Devices in Anterior Cruciate Ligament Reconstruction: Part II: Tibial Site
Am. J. Sports Med., March 1, 2003; 31(2): 182 - 188.
[Abstract] [Full Text] [PDF]


Home page
Am J Sports MedHome page
J. T. Nurmi, T. L. N. Jarvinen, P. Kannus, H. Sievanen, J. Toukosalo, and M. Jarvinen
Compaction Versus Extraction Drilling for Fixation of the Hamstring Tendon Graft in Anterior Cruciate Ligament Reconstruction
Am. J. Sports Med., March 1, 2002; 30(2): 167 - 173.
[Abstract] [Full Text] [PDF]


Home page
Am J Sports MedHome page
J. B. Selby, D. L. Johnson, P. Hester, and D. N.M. Caborn
Effect of Screw Length on Bioabsorbable Interference Screw Fixation in a Tibial Bone Tunnel
Am. J. Sports Med., September 1, 2001; 29(5): 614 - 619.
[Abstract] [Full Text] [PDF]


Home page
Am J Sports MedHome page
P. Kousa, T. L.N. Jarvinen, P. Kannus, and M. Jarvinen
Initial Fixation Strength of Bioabsorbable and Titanium Interference Screws in Anterior Cruciate Ligament Reconstruction: Biomechanical Evaluation by Single Cycle and Cyclic Loading
Am. J. Sports Med., July 1, 2001; 29(4): 420 - 425.
[Abstract] [Full Text] [PDF]




HOME HELP CONTACT US SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1999 by the American Orthopaedic Society for Sports Medicine.