AJSM signin
HOME HELP CONTACT US SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Sign In to gain access to subscriptions and/or personal tools.
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Draganich, L. F.
Right arrow Articles by Reider, B.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Draganich, L. F.
Right arrow Articles by Reider, B.
The American Journal of Sports Medicine 22:627-631 (1994)
© 1994 SAGE Publications

The Effect of Thigh and Goniometer Restraints on the Reproducibility of the Genucom Knee Analysis System

Louis F. Draganich, PhD

University of Chicago Medical Center, Department of Surgery, Section of Orthopaedics and Rehabilitation Medicine, Chicago, Illinois

Michael R. Sathy, MD

University of Chicago Medical Center, Department of Surgery, Section of Orthopaedics and Rehabilitation Medicine, Chicago, Illinois

Bruce Reider, MD

University of Chicago Medical Center, Department of Surgery, Section of Orthopaedics and Rehabilitation Medicine, Chicago, Illinois

We compared the reproducibility of measurements made with the Genucom knee analysis system using two methods of restraint. The first method was that sug gested by the manufacturer and consisted of clamping the thigh to the examination chair with 70 N of vertical force and 110 N of mediolateral force and used a single elastic strap to secure the electrogoniometer cuff to the leg. In the second, or enhanced, method, the vertical and mediolateral clamping forces were each increased to 156 N, and an additional strap was used to secure the cuff to the leg. Tests performed were the anteroposte rior stress tests at 20° and 90° of knee flexion, and the varus-valgus stress test, the internal-external rotation stress test, and the medial and lateral pivot shift tests at 20°. Five normal subjects were installed and tested on 6 different days with the manufacturer's suggested se curing method and on 12 different days with the en hanced securing method. The enhanced method of re straint resulted in significantly reduced day-to-day variance for all tests performed except the varus-valgus stress test.